RDL-2000 Installation Guidelines
70-00144-01-01 Proprietary Redline Communications © 2011 Page 32 of 52 March 9, 2011
4.5.2 System Grounding
A grounding connection is located on the RDL-2000 chassis. Use this screw to terminate
a grounding wire.
Correct grounding is very important for safe operation of wireless equipment -- ensure
standards.
The following general industry practices are provided as a guideline only:
1. All grounding connections must be made in accordance with local and national
standards. Painted or dirty surfaces should be cleaned thoroughly down to bare
metal and screws should be well tightened.
2. Provide a direct ground connection from the antenna-mounting bracket, the RDL-
2000 unit, and any lightning protection equipment, to the same
ground point on the
tower. Use the grounding screw on the antenna bracket and the grounding screw on
the RDL-2000 to terminate the ground wires. Avoid making sharp bends in the
ground wires.
4.5.3 Lightning Protection Guidelines
All outdoor wireless equipment is susceptible to lightning damage. Lightning protection
and grounding practices per the local and national electrical codes serve to minimize
possible equipment damage, service outages, and serious injury. Common reasons for
these damages can be summarized as follows:
- Tower/Antenna sites that are not grounded properly may conduct high lightning strike
energy.
- Lack of installed lightning protection equipment may cause equipment failures
resulting from lightning induced currents.
The grounding system should provide a low-impedance path to ground for the lightning-
induced current. A loose ground connection is a source of noise and may cause
sensitive equipment to malfunction.
The tower grounding system disperses most of the surge energy from a tower strike
away from the building and equipment. The remaining energy on the Ethernet cable
shield and center conductor can be directed safely to ground by using a lightning
arrestor in series with the Ethernet cable.
Grounding Guidelines
This equipment must be installed by a qualified professional installer and follow
safety requirements and/or use of non-standard practices and procedures could
result in personal injury
and damage
system.
The following general industry practices are provided as a guideline only.
- All grounding connections must
be made in accordance with local/national
standards.
- Painted or dirty surfaces should be cleaned thoroughly down to bare metal and
screws should be well tightened.